1-800-261-1041  
 

Car Washes and Lube Shops - Waste Oil Boiler and Heater Installations

These car wash and lube shops are saving thousands of dollars every year in heating costs and have eliminated their used oil disposal expenses. They heat their shops and car wash water with boilers fired by waste oil recycled on site from their own lube shop. Utility bill savings for heat and car wash hot water typically pay for a new system in 24 - 36 months. With minimal maintenance, waste oil burning boilers run for decades. Radiant floor heat is cost-effective in new facilities. Unit heaters are cost-effective for new and existing lube shops. Click photo thumbnails to see larger photos and photo captions.

Rainford's Lube-Oil

Yakima, Washington

Equipment: Columbia WL-60 waste oil fired boiler with Firelake/Shenandoah B-10 burner

Project: Supply and install radiant floor heating, frost pads, and hydronic heaters in lube shop and heat hot water for car wash. Radiant floor heat and frost pads melt snow and ice and help dry up standing water to reduce slips and falls in the lube shop.

 
  • Columbia/Shenandoah WL-60 boiler provides radiant floor heat in quick lube and heats hot water for car wash.
  • Hydronic unit heater.
  • Rainford's three bay oil change shop and car wash saves thousands on heating costs and eliminated their used oil disposal expenses.



 


Wash & Lube Time

Bend, Oregon

Equipment: Columbia WL-60 waste oil fired boiler with Firelake/Shenandoah B-10 burner.

Project: Supply and install waste oil fired boilers to reuse all used automotive oils onsite. Waste oil is recycled in their new boiler to heat the facility and heat the water for the car wash.

 
  • Columbia WL-60 boiler with Firelake/Shenandoah B-10 burner. All automotive fluids are recycled onsite and used as fuel in the burner/boiler.
  • Wash & Lube Time oil change and car wash.
  • Four bay oil change and car wash using waste oil to heat their building and car wash water.



 


Classy Chassis -
Xpress Lube & Car Wash

Lakewood, Washington

Equipment: Columbia WL-60 waste oil fired boiler with Shenandoah B-10 burner

Project: Supply and install radiant floor heating for 3-bay oil change shop, hot water for car wash, and snow and ice melt outside of bay entries.

 
  • PEX tubing laid out; ready to pour concrete floor.
  • Radiant floor manifold and PEX tubing in place ready for concrete floor to be poured.
  • The start of the concrete pour.
  • Concrete pour in progress.
  • Finished concrete pour.
  • Radiant heat manifold in finished concrete floor.
  • PEX tubing, prior to concrete pour, laid out for snow and ice melt outside the oil change bay entry ways.
  • Columbia/Shenandoah WL-60 boiler for radiant floor heat in quick lube, snow and ice melt, and car wash hot water.
  • Classy Chassis finished facility.



 

Auto Spa

Yakima, Washington

Equipment: 2 Columbia WL-60 waste oil fired boilers with Firelake/Shenandoah B-10 burners

Project: Supply and install radiant floor heat for two bay oil change shop and hot water for two bay car wash.

 
  • 2 Columbia/Shenandoah WL-60 boilers provide radiant floor heat in quick lube and heats hot water for car wash.
  • Auto Spa’s four bay oil change shop and car wash saves thousands every year by recycling their used oil onsite into heat.



 

View more photo galleries or contact us to talk with a waste oil heating specialist to discover how much your car wash and lube shop can reduce heating and disposal costs using waste oil fired boilers and heaters.

Home Brewery & Distillery Boilers Parts Specials Gallery Contact Us
About Us Used Oil Heat Overview Parts Store Financing References Quote Request
Customer Service Used Oil Heaters & Boilers Service Resources    
  Radiant Floor Heat   Events    
  Industrial Fans        
  Biodiesel Boilers        

Northwest Industrial Equipment, Inc.

(253) 872-6060

22020 – 68th Avenue South, Kent, WA 98032
© Copyright 2012 - , Northwest Industrial Equipment - All Rights Reserved. Website Design, Hosting and Maintenance by New Tech Web, Inc.